Ruhof Endozime SLR Endoscopy Bedside Care Kit

Ordering Details :

     

Cat. No. 345EPONS
Cat. No. 345EPO500

250ml Kit 24 Units
500ml kit 24 Units

NHS Supply Chain Code. FAL725
NHS Supply Chain Code. FAL6990

   ORDER NOW
   ORDER NOW

The Only Endoscopy Bedside Care Kit That Removes Synthetic Lipids From Scope Surface And Internal Channels.

Phase One of Scope Cleaning!

The kit is designed for convenient bedside use to remove all contaminants from the outside sheath and inside channel of scopes. The kit contains an Endozime SLR sponge to remove soil from the insertion tube and Endozime SLR enzymatic solution for suctioning through the channels.

The kit provides optimal cleaning, preventing dried on soil, before the scope is transported for reprocessing.

ENDOZIME® SLR is the only enzymatic detergent designed to molecularly displace synthetic lipids, allowing them to be rinsed off while dissolving blood, fat, carbohydrates, starches and protein. ENDOZIME® SLR SPONGES are custom made to contour the outside sheath of a scope.

Features and Benefits

  • Begins cleaning on contact, preventing soil from drying on scope surfaces.
  • Removes gross contaminants, including synthetic lipids.
  • Uniquely fitted for all scopes: flexible/rigid.
  • Safe on all scopes.
  • Neutral pH, non-abrasive, 100% Biodegradable.
  • Empty containers can be rinsed and recycled.
  • Will not harm any metals, plastic, rubber, corrugated tubing, glass or mirrors.

Each kit is individually packaged for one time use, eliminating the risk of cross-contamination. 500ml kit is compatible with Olympus flexible scope reprocessing instructions.

CONTENTS - 250ml Kit

Endozime SLR Sponge - contoured sponge for cleaning outside sheath of scope.
Endozime SLR – 250 ml of pre-diluted enzymatic detergent.

INSTRUCTIONS FOR USE

  1. Immediately after a procedure, wipe the insertion tube with the Endozime® SLR Sponge soaked in prepared enzymatic solution.
  2. Place the distal end of the endoscope into the Phase One canister and suction the Endozime® SLR enzymatic solution through the biopsy/suction channel until canister is empty.
  3. Flush water and air into the air/water channel in accordance with the endoscope manufacturer's instructions.
  4. The sponge should be discarded in the waste container. Empty containers should be discarded in a waste container or offered for recycling if possible. Do not use empty containers for other purposes.
  5. The scope should then be placed in a soiled scope bag/container and removed to the reprocessing area.

CONTENTS - 500ml Kit

Endozime SLR Sponge - contoured sponge for cleaning outside sheath of scope.
Endozime SLR – 500 ml of pre-diluted enzymatic detergent.

INSTRUCTIONS FOR USE

  1. Immediately after a procedure, wipe the insertion tube with the Endozime® SLR Sponge soaked in prepared enzymatic solution.
  2. Place the distal end of the endoscope into the Phase One canister and suction the Endozime® SLR enzymatic solution through the biopsy/suction channel for 30 seconds.
  3. Flush water and air into the air/water channel in accordance with the endoscope manufacturer's instructions.
  4. The sponge should be discarded in the waste container. Empty containers should be discarded in a waste container or offered for recycling if possible. Do not use empty containers for other purposes.
  5. The scope should then be placed in a soiled scope bag/container and removed to the reprocessing area.

Ruhof Endozime SLR Endoscopy Bedside Care Kit 500ml
Ruhof Endozime SLR Endoscopy Bedside Care Kit 500ml
Please Click On Image For Larger Version

Ruhof Endozime SLR Endoscopy Bedside Care Kit 500ml
Ruhof Endozime SLR Endoscopy Bedside Care Kit 500ml In Use

Ruhof Endozime SLR Endoscopy Bedside Care Kit 500ml
Ruhof Endozime SLR Endoscopy Bedside Care Kit 500ml In Use